Skip to main content Skip to search Skip to main navigation
Product features
Design of control output: PNP/NPN + IO-Link
Design of the electrical connection: Steckanschluss
Operating voltage type: DC
Physical measurement principle of the sensor: kalorimetrisch / Bypass-Konstruktion
Pressure monitoring included: Nein
certificate/approval: CE, United Kingdom Conformity Assessed (UKCA), c UL
degree of protection: IP40
end value of the measuring range (flow rate): 100 l/min
flow control valve function: flow control valve
initial value of the measuring range (flow rate): 1 l/min
max. ambient temperature: 50 °C
max. electricity consumption: 35 mA
max. medium temperature: 50 °C
max. operating pressure: 0.75 MPa
max. operating voltage with DC: 30 V
max. storage temperature: 60 °C
min. operating pressure: -0.1 MPa
min. operating voltage with DC: 18 V
min. storage temperature: -10 °C
operating medium: argon, compressed air, compressed air, nitrogen (N2)
pneumatic port: for tubing outside-Ø 8 mm
short-circuit strength available: Yes
style of communication interface: IO-Link
temperature monitoring of the medium present: No
type of indication: LCD
weight: 0.083 kg
Product information "PF2M711S-C8-LN"
This PF2M7 model is equipped with IO-Link communication, allowing for seamless integration into industrial networks. It provides real-time flow data and diagnostic information for dry air and inert gases. The 2-color display enhances local monitoring capabilities.

• Type: Digital flow sensor
• Feature: IO-Link compatible
• Fluid: Air / Inert gases
• Data: Flow & Diagnostics

Report an error

Thank you for helping us improve our website. Please provide as much detail as possible regarding item PF2M711S-C8-LN, PF2M711S-C8-LN.

Please enter your name and your e-mail address. We may contact you regarding your report for clarification.