Skip to main content Skip to search Skip to main navigation
Product features
Design of control output: PNP/NPN + IO-Link
Design of the electrical connection: M12 Stecker
Operating voltage type: DC
Physical measurement principle of the sensor: kalorimetrisch / Bypass-Konstruktion
Pressure monitoring included: Nein
analog output voltage: 1 ... 5 V, 1 ... 5 V
certificate/approval: CE, United Kingdom Conformity Assessed (UKCA), c UL
degree of protection: IP65
end value of the measuring range (flow rate): 6000 l/min
initial value of the measuring range (flow rate): 60 l/min
max. ambient temperature: 50 °C
max. electricity consumption: 150 mA
max. medium temperature: 50 °C
max. operating pressure: 1.5 MPa
max. operating voltage with DC: 30 V
max. storage temperature: 60 °C
min. operating pressure: 0.1 MPa
min. operating voltage with DC: 21.6 V
min. storage temperature: -10 °C
number of analogue outputs: 1
number of switching inputs: 1
operating medium: argon, compressed air, compressed air, nitrogen (N2)
pneumatic port: G 1 1/2
short-circuit strength available: Yes
style of communication interface: IO-Link
temperature monitoring of the medium present: No
type of indication: LCD
weight: 1.22 kg
Product information "PF3A706H-F14-L3N"
This PF3A7*H-L model features a rotatable 3-color display for easy reading in any mounting orientation. Combined with IO-Link, it offers comprehensive flow monitoring capabilities for large air lines, supporting digital transformation initiatives.

• Type: Large flow sensor
• Display: Rotatable 3-color
• Connectivity: IO-Link
• Enhanced visibility

Report an error

Thank you for helping us improve our website. Please provide as much detail as possible regarding item PF3A706H-F14-L3N, PF3A706H-F14-L3N.

Please enter your name and your e-mail address. We may contact you regarding your report for clarification.